Excessive exposure to radio frequency (RF) energy can damage human tissue. To prevent this, many countries around the world have introduced standards that limit the amount of RF exposure allowed from transmitters of all types. BTF can help determine if your product meets those requirements. We perform the required testing for a variety of portable and mobile telecommunications equipment with state-of-the-art equipment, using cutting edge technology, providing you with accurate and dependable RF exposure measurements. BTF is one of the few organizations capable of testing and certifying your product to RF exposure standards, as well as electrical safety standards and FCC requirements.
RF exposure is evaluated using a “phantom” that simulates the electrical characteristics of the human head or body. The RF energy penetrating the “phantom” is monitored by precisely positioned probes that measure Specific Absorption Rate in watts per kilogram of tissue.
FCC SAR
In the United States, the FCC regulates SAR under 47 CFR Part 2, section 2.1093. Products intended for general use must meet a SAR limit of 1.6 mW/g averaged over one gram of tissue in any part of the head or body, and 4 mW/g averaged over 10 grams for hands, wrists, feet and ankles.
In the European Union, RF exposure limits have been established by Council Recommendation 1999/519/EC. Harmonized standards cover the most common products such as cell phones and RFID devices. The limits and methods of RF exposure evaluation in the EU are similar but not identical to those in the US.
Maximum Permissible Exposure (MPE)
When users are typically positioned further away form the radio transmitter, typically more than 20cm, the method of RF exposure evaluation is termed Maximum Permissible Exposure (MPE). In many cases MPE may be calculated from transmitter output power and antenna type. In some cases, MPE must be measured directly in terms of electric or magnetic field strength or power density, depending on the operating frequency of the transmitter.
In the United States, the FCC rules for MPE limits are found in 47 CFR Part 2, section 1.1310. Mobile devices, which are more than 20 cm from the user and are not in a fixed location, such as tabletop wireless nodes, are also governed by section 2.1091 of the FCC rules.
In the European Union, Council Recommendation 1999/519/EC contains the exposure limits for fixed and mobile transmitters. The harmonized standard EN50385 applies limits to base stations operating in the frequency range 110MHz to 40 GHz.
BTF Testing Lab, our company has electromagnetic compatibility laboratories, safety regulations Laboratory, wireless radio frequency Laboratory, battery Laboratory, chemical Laboratory, SAR Laboratory, HAC Laboratory, etc. We have obtained qualifications and authorizations such as CMA, CNAS, CPSC, VCCI, etc. Our company has an experienced and professional technical engineering team, which can help enterprises solve the problem. If you have relevant testing and certification needs, you can directly contact our Testing staff to obtain detailed cost quotations and cycle information!